Ceiling Insulation Requirements in New Zealand
How much ceiling insulation your home needs depends on what kind of home it is. New homes are built to an R6.6 benchmark. Rentals must meet the Healthy Homes standards. For a home you own and live in, there is no legal minimum, but clear guidance exists on when to add more.
Ceiling insulation requirements at a glance.
The Building Code benchmark for new-home ceilings is R6.6 in every climate zone, from Northland to Southland.
The Healthy Homes standards require R2.9 in most of the North Island and R3.3 on the central plateau and in the South Island.
There is no legal minimum. If your ceiling insulation is under 120mm thick or patchy, it’s worth adding more. Safe-R recommends topping up to at least R6.6.
New homes and the Building Code.
New homes must meet clause H1 of the Building Code, which covers energy efficiency. Since 1 May 2023 the benchmark for roofs and ceilings has been R6.6 in all six climate zones. Before that, most of the North Island only needed R2.9.
Since 27 November 2025, the updated Acceptable Solution H1/AS1 (6th edition) no longer includes the schedule method. New homes are now designed with a calculation method. The older edition can still be used for consent applications until 26 November 2026.
A new home is compared with a reference home that has an R6.6 ceiling. Designers can trade ceiling performance for better walls, floors or windows, down to R2.6 at the lowest for any part of the roof. That’s why R6.6 is the benchmark new homes are designed around.
- 1 April 1978Compulsory in new homes, R1.9 until 2007
- 2007 to 2008Most of the North Island moves to R2.9
- 1 May 2023R6.6 benchmark in all six climate zones
- 27 November 2025H1/AS1 6th edition, calculation method
- 26 November 2026Older edition last date for consent applications

Most of the North Island
Central plateau and South Island
At least 120mm thick, unless it met the minimum R-value when installed and has lost no more than 30% of its thickness.
Rental homes and the Healthy Homes standards.
Every private rental must have ceiling insulation that meets the Healthy Homes insulation standard. The minimum is R2.9 in most of the North Island. On the central plateau (Taupō, Ruapehu and northern Rangitīkei) and across the whole South Island, it’s R3.3. Check your zone with the Tenancy Services insulation tool.
Ceiling insulation installed before 1 July 2016 must be at least 120mm thick, unless the landlord can show it met the minimum R-value when installed and has lost no more than 30% of its thickness. It must also be in reasonable condition. Insulation must be installed to NZS 4246:2016, the New Zealand standard for installing insulation in homes.
Landlords who top up or install ceiling insulation in an existing rental must meet the Healthy Homes standard. A top up does not have to meet the Building Code figures for new homes. If you build an addition or a new roof under building consent, the new work has to meet the current Building Code. The rest of your existing home does not have to be brought up to that level. Read more about insulation for rental properties.
Homes you own and live in.
There is no legal minimum for ceiling insulation in a home you own and live in. Adding insulation to an existing ceiling usually doesn’t need building consent.
Safe-R recommends topping up your ceiling insulation to at least R6.6. That is the ceiling figure the Building Code’s Acceptable Solution H1/AS1 uses as the reference for new homes, so it is a sound target for an existing home too. Your home does not have to meet it. What suits you depends on what is in your ceiling now, your Healthy Homes obligations if you rent the home out, and what you want from the job. Our team will work through it with you.
EECA, the government’s energy agency, suggests using the rental and new-home figures as a guide and going higher where you can. One simple check is thickness. If your ceiling insulation is less than 120mm thick, or sits below the top of the ceiling joists, it’s worth adding more. Insulation settles and compresses over time, so a ceiling that was well insulated years ago may not be now.
The easiest fix is usually topping up your ceiling insulation. For the rest of the house, see retrofit insulation for existing homes. Walls are the next place to look. See wall insulation NZ with CosyWall.

Get a ceiling insulation quote.

What the R-value numbers mean.
An R-value measures how well insulation resists heat flow. The higher the number, the better it insulates. The Building Code figures are construction R-values, for the whole ceiling including framing and lining. The figure on an insulation product is for the insulation on its own, so your installer works out the depth your ceiling needs. Find out how R-values work.

Meeting the requirements with Loft.
Loft is Safe-R’s blown ceiling and roof insulation. Because it is blown into the roof space, it can be installed to whatever depth your ceiling needs. Loft can be blown to R6.6 and well beyond, and it goes much further for high-performance homes. R6.0 is about 294mm deep, and Loft is rated all the way to R15.0 at 735mm. The full thickness table is in the Loft technical specifications.
About 294mm deep
735mm deep
Try our ceiling insulation cost calculator. Calculators provide an indicative cost only. For a formal quote, please contact the Safe-R Insulation team.
Ceiling insulation requirements FAQs.
Have another question? Call 0800 267 992 or read our full FAQ.
It depends on the home. New homes are built to an R6.6 benchmark. Rentals need R2.9 in most of the North Island and R3.3 on the central plateau and in the South Island. Homes you own and live in have no legal minimum.
In a rental, ceiling insulation installed before 1 July 2016 must be at least 120mm thick, unless the landlord can show it met the minimum R-value when installed and has lost no more than 30% of its thickness. In your own home, under 120mm is a good sign it’s time to add more. The depth needed for a given R-value depends on the product. For Loft, R6.0 is about 294mm.
Usually not. Adding insulation to the ceiling of an existing home doesn’t normally need building consent. The work should still be done to NZS 4246:2016.
No. R6.6 is the benchmark for new homes, and a home you already live in doesn’t have to be upgraded to it. Building work under a consent has to meet the current Building Code for the new work, but the rest of the house does not have to be upgraded. Safe-R recommends topping up to at least R6.6, and our team will work through what suits your home. EECA suggests using the new-home and rental figures as a guide when you add insulation, and going higher where you can.
Yes. Loft can be installed over existing batt or segment type products. Your installer checks what’s already there first.
Get a ceiling insulation quote.
Not sure what’s in your ceiling now? Your local Safe-R installer checks your roof space and tells you what it needs. Most projects are completed within a day or two.